| Product Name | 125kW bidirectional DC-DC converter |
| Model Number | BIDC1500100 |
| DC bus side (Rated voltage) | 1500VDC |
| Working voltage range | 500V~1500VDC |
| Battery pack side (Rated voltage) | 1250VDC |
| Working voltage range | 500V to 1500VDC |
| Rated power | 125KW@1250V |
| Rated current (low voltage side) | 100A |
| Efficiency | Peak ≥99.2% |
| Dimensions (W × H × L) | 350×85×600mm |
|
| Wide power range efficiency up to 99.2% |
| CEC efficiency >99% |
|
| Short circuit protection |
| Fault current ms-level cut-off capability |
| Short-circuit capacity I²t<50A²s |
|
| 6.34kW/L, forced air cooling |
| Integrated control unit, power relay, fuse |
|
| Supports parallel operation for current balancing |
| Supports constant current and constant voltage charging and discharging |
| Integrated MPPT algorithm for photovoltaic maximum power generation. |
|
| IEC 62477-1 |
| DC busbar side (Port A) | |
| Rated voltage | 1500VDC |
| Working voltage range | 500V~1500VDC |
| Battery pack side (Port B) | |
| Rated voltage | 1250VDC |
| Working voltage range | 500V to 1500VDC |
| Bidirectional conversion performance | |
| Rated power | 125KW@1250V) |
| Rated current (low voltage side) | 100A |
| Efficiency | Peak ≥99.2% |
| Power response time | ≤5ms |
| Mechanical specifications | |
| Dimensions (W × H × L) | 350×85×600mm |
| G.W | <15kgs |
| Environmental parameters | |
| Operating temperature | -25 to 55 ° C (current derating above 40 ° C /45 °C) |
| Operating humidity | 5% ~ 85% |
| Noise | <70dB, ring temperature <30 ° |
| C <75dB, peak | |
| Pollution level | PD2 |
| Overvoltage level | OVII |
SunCare Hospital, a leading healthcare institution committed to sustainable operations and patient well-being, partnered with us to transition its energy source to solar. The project involved the full design and installation of a customized solar power system to reduce operating costs, increase energy reliability, and support the hospital's green initiatives.
This project was designed to meet the hospital’s energy needs while promoting sustainability, reducing costs, and ensuring uninterrupted service for patients and essential medical operations.
We provided a complete solar solution tailored to the hospital’s needs, ensuring performance, safety, and long-term energy savings without disrupting daily operations.
We analyzed usage patterns and infrastructure to design a system that meets specific energy needs.
Our team installed efficiently with zero interruption to hospital operations and strict safety procedures.
We created a solar layout that maximizes efficiency while matching the hospital’s structure and goals.
We integrated smart monitoring and backup support to ensure continuous power for critical medical equipment.
This project is more than just an energy upgrade, it is a commitment to health, sustainability, and community leadership. The SunCare Hospital solar installation reflects how renewable energy can enhance essential services without compromise.
Solarize brings cutting-edge clean energy solutions to life, empowering homes, businesses, and public spaces with sustainable power that transforms everyday living.