BIM15060 is a single-phase AC-DC bidirectional converter that directly connects to the power grid and the battery. The power grid can charge the battery through this converter, and the battery can discharge to the power grid through it. It features high performance, high reliability and high power density
| BIM15060 | |
|---|---|
| Basic Parameters | |
| Dimensions | 44mm141.4mm333mm |
| Weight | 1.5kg |
| Cooling | Air cooling |
| Operating temperature | -40~70°C, derating above 45°C |
| Relative humidity | 0~95%, no condensation |
| Altitude | ≤4000m, derating above 2000m |
| Efficiency | Overall efficiency ≥91%; Inverter efficiency ≥91% |
| Output voltage accuracy | ±1% |
| Output current accuracy | ±1% |
| Rectification/inversion mode switching time | 10ms |
| Input/Output Characteristics | |
| Rectification Mode | |
| AC input voltage range | 176~264Vac |
| Input frequency range | 50/60Hz, ±3Hz |
| Power factor (cosΦ) | ≥0.99 |
| Current harmonic distortion (THDI) | ≤3% |
| Output voltage range | 5~150Vdc |
| Maximum output power | 3000W |
| Maximum output current | 60A |

| Input Characteristics | |
| DC input voltage range | 5-150Vdc |
| Maximum input current | 60A |
| Maximum input power | 3000W |
| Output Characteristics | |
| AC grid-connection voltage range | 176~264Vac |
| AC grid-connection frequency range | 50/60Hz±3Hz |
| AC grid-connection THDI | ≤3% |

SunCare Hospital, a leading healthcare institution committed to sustainable operations and patient well-being, partnered with us to transition its energy source to solar. The project involved the full design and installation of a customized solar power system to reduce operating costs, increase energy reliability, and support the hospital's green initiatives.
This project was designed to meet the hospital’s energy needs while promoting sustainability, reducing costs, and ensuring uninterrupted service for patients and essential medical operations.
We provided a complete solar solution tailored to the hospital’s needs, ensuring performance, safety, and long-term energy savings without disrupting daily operations.
We analyzed usage patterns and infrastructure to design a system that meets specific energy needs.
Our team installed efficiently with zero interruption to hospital operations and strict safety procedures.
We created a solar layout that maximizes efficiency while matching the hospital’s structure and goals.
We integrated smart monitoring and backup support to ensure continuous power for critical medical equipment.
This project is more than just an energy upgrade, it is a commitment to health, sustainability, and community leadership. The SunCare Hospital solar installation reflects how renewable energy can enhance essential services without compromise.
Solarize brings cutting-edge clean energy solutions to life, empowering homes, businesses, and public spaces with sustainable power that transforms everyday living.