Project Detail

Home – Project Detail

Product Name 3kW bidirectional ac to dc converter
Model Number BIM48-3000
DC Rated voltge 48Vdc
Inverter output voltage 100V/120V/220V/240V
Ac input voltage (Rectification (charging)) 90~260Vac
 Rated Power 3KW
Rated frequency 50Hz/60HZ
Dimension   304*174*69.8mm(L*W*H)

This 3kW bidirectional ac to dc converter is a multi-functional bidirectional PCS module, using efficient soft switch patent topology and digital control technology, integrated pure sine wave inverter, high-power charger, UPS bypass, RS485 and CAN communication port, parallel and other functions. Can achieve rectified (charging) 90-264Vac wide range input, inverter (discharge) 100-240Vac wide range output, two-way AC load and DC load power is the same, off-grid inverter mode, instantaneous peak power with load up to 1.5 times of rated. It has the advantages of high efficiency, high power density, high reliability, low noise and so on.

ITEM Model No. BIM48-3000
Output power Inverter power 3000W
Charging power 3000W
Inverter Inverter output voltage 100Vac, 110Vac, 120Vac, 220Vac, 230Vac, 240Vac (optional)
Inverter output frequency 50Hz, 60Hz (optional)
Overload capability 100% < P <= 110% peak power, duration 20s
110% < P <= 125% peak power, duration 5s
125% < P <= 150% peak power, duration 2s
150% < P <= 200% peak power for 200ms duration
Output waveform Pure sine wave
ThdU 3%@ resistive load
Efficiency Max.91.2% @120Vac, Max.93.5% @220Vac
Parallel Supports 6 wired parallel machines
Rectifier(Charging) Ac input voltage 90-264Vac
Ac frequency range 47-63Hz
Maximum AC input current 30A (relaxed to 30A, but the system design needs to consider safety regulations, such as the maximum AC input 15A in the United States, the maximum AC input current 16A in China)
PF 0.99@100% Load
ThdI <5%@100% Load
Maximum charging current 60A
Charging voltage range 40-59.5 Vdc
Voltage Ripple Max.700mV (0-20MHz)
Efficiency Max.92.5% @120Vac, Max.94.5% @220Vac
Charge Management Upper computer management
AC bypass switching AC Bypass current Max.15A
Switching time Typical 20ms
Environmental conditions Operating temperature -25℃ ~ +70℃, above 45℃ need derating use
Storage temperature -40℃ ~ +70℃
Relative humidity ≤ 95% RH, no condensation
Cooling method Forced air cooling
Altitude 2000m, the maximum working environment will be reduced by 1℃ for every 200m elevation increase above 2000m.

Project Overview

SunCare Hospital, a leading healthcare institution committed to sustainable operations and patient well-being, partnered with us to transition its energy source to solar. The project involved the full design and installation of a customized solar power system to reduce operating costs, increase energy reliability, and support the hospital's green initiatives.

Project Objectives

This project was designed to meet the hospital’s energy needs while promoting sustainability, reducing costs, and ensuring uninterrupted service for patients and essential medical operations.

Key Results & Benefits

What We Delivered

We provided a complete solar solution tailored to the hospital’s needs, ensuring performance, safety, and long-term energy savings without disrupting daily operations.

Custom Energy Assessment

We analyzed usage patterns and infrastructure to design a system that meets specific energy needs.

Seamless Installation Without Disruption

Our team installed efficiently with zero interruption to hospital operations and strict safety procedures.

Tailored Solar System Design

We created a solar layout that maximizes efficiency while matching the hospital’s structure and goals.

Reliable Backup and Monitoring System

We integrated smart monitoring and backup support to ensure continuous power for critical medical equipment.

Our Impact

This project is more than just an energy upgrade, it is a commitment to health, sustainability, and community leadership. The SunCare Hospital solar installation reflects how renewable energy can enhance essential services without compromise.

Client Testimonial

"Working with Solarize was a smooth experience. Their team truly understood our hospital’s needs and delivered a solution that saves energy, ensures reliability, and supports our long-term sustainability goals."

Dr. Lisa
Director of Operations, SunCare Hospital
Other Projects

Energizing Communities Through Innovation

Solarize brings cutting-edge clean energy solutions to life, empowering homes, businesses, and public spaces with sustainable power that transforms everyday living.

BrightMall Complex

Location: Lisbon, Portugal
Solar rooftop installation across a large-scale shopping mall to reduce grid dependency and promote sustainable retail operations. Integrated with smart energy monitoring for maximum efficiency.

SunCare Hospital

Location: Melbourne, Australia
Development of a solar-battery hybrid system for uninterrupted power in critical hospital zones, including ICUs and emergency rooms. Designed to meet high safety and reliability standards.

EcoBank Tower

Location: Nairobi, Kenya
Solar façade and rooftop system installed on a 20-story corporate office building, integrated with energy-efficient HVAC systems to reduce operational carbon footprint.

GreenForge Factory

Location: Hamburg, Germany
Large-scale solar installation for a metal fabrication plant, optimized to meet industrial energy demand while supporting Germany’s renewable transition goals. Includes automated load balancing.