Project Detail

Home – Project Detail

Product Name 50KW /60KW Microgrid Hybrid Inverter
Model Number  IM50KFCM3 / IM60KFCM3
Battery Rated voltge range 350V~820V
PV side MPPT voltage range 200V-800V
AC side Voltage(On Grid) 400Vac/230Vac
AC side  Rated Power(On Grid) 50KW / 60KW
Rated frequency 50Hz/45HZ~55HZ, 60HZ/55HZ-65HZ
Dimension 440*200*670mm(W*H*D)

50KW/60KW Solar Hybrid inverter , An efficient and highly reliable energy storage inverter mainly developed or small and medium-sized energy storage microgrids.It supports photovoltaic access,contains a parallel and off-grid switching device,supports multiple parallel operation,supports oil-engine hybrid operation,and supports parallel and off-grid switching.Fast off-grid switching.It is suitable for various scenarios such as small industry and commerce,small island microgrids,farms,villas,and battery cascade utilization to meet the needs of different users.

Parameters IM60KFCM3 IM50KFCM3
Battery parameters
Battery voltage(Max.) 850V
Battery voltage(Min.) 200V
Rated battery voltage range 420V-820V 350V-820V
Battery current(Max.) 150A 150A
PV  parameter
Power(Max.) 38.4 kW + 38.4 kW
PV voltage(Max.) 850V
PV  starting voltage 250V
MPPT voltage range 200V-800V
PV current(Max.) 64A+64A
Ac side (On-grid)
Rated power 60kVA 50kVA
Rated current 87A 73A
Rated grid voltage 400V/230V
Grid voltage range – 20% ~ 20%
50Hz/47Hz~52Hz(60Hz/57Hz~62Hz)
Grid frequency range
Current harmonics <3%
Power factor -1 to 1 (see Figure 3)
Ac side (off-grid)
Rated power output 60kVA 50kVA
Power output(Max.) 66kVA 55kVA
Rated output current 87A 73A
Output current(Max.) 96A 80A
Rated voltage 400V/230V
Output voltage harmonics <3%(resistive load)
Unbalance degree 100%
Frequency range 50/60Hz
Output overload (current) Ie* 1.1 <Iload≤Ie* 1.25100s

Project Overview

SunCare Hospital, a leading healthcare institution committed to sustainable operations and patient well-being, partnered with us to transition its energy source to solar. The project involved the full design and installation of a customized solar power system to reduce operating costs, increase energy reliability, and support the hospital's green initiatives.

Project Objectives

This project was designed to meet the hospital’s energy needs while promoting sustainability, reducing costs, and ensuring uninterrupted service for patients and essential medical operations.

Key Results & Benefits

What We Delivered

We provided a complete solar solution tailored to the hospital’s needs, ensuring performance, safety, and long-term energy savings without disrupting daily operations.

Custom Energy Assessment

We analyzed usage patterns and infrastructure to design a system that meets specific energy needs.

Seamless Installation Without Disruption

Our team installed efficiently with zero interruption to hospital operations and strict safety procedures.

Tailored Solar System Design

We created a solar layout that maximizes efficiency while matching the hospital’s structure and goals.

Reliable Backup and Monitoring System

We integrated smart monitoring and backup support to ensure continuous power for critical medical equipment.

Our Impact

This project is more than just an energy upgrade, it is a commitment to health, sustainability, and community leadership. The SunCare Hospital solar installation reflects how renewable energy can enhance essential services without compromise.

Client Testimonial

"Working with Solarize was a smooth experience. Their team truly understood our hospital’s needs and delivered a solution that saves energy, ensures reliability, and supports our long-term sustainability goals."

Dr. Lisa
Director of Operations, SunCare Hospital
Other Projects

Energizing Communities Through Innovation

Solarize brings cutting-edge clean energy solutions to life, empowering homes, businesses, and public spaces with sustainable power that transforms everyday living.

BrightMall Complex

Location: Lisbon, Portugal
Solar rooftop installation across a large-scale shopping mall to reduce grid dependency and promote sustainable retail operations. Integrated with smart energy monitoring for maximum efficiency.

SunCare Hospital

Location: Melbourne, Australia
Development of a solar-battery hybrid system for uninterrupted power in critical hospital zones, including ICUs and emergency rooms. Designed to meet high safety and reliability standards.

EcoBank Tower

Location: Nairobi, Kenya
Solar façade and rooftop system installed on a 20-story corporate office building, integrated with energy-efficient HVAC systems to reduce operational carbon footprint.

GreenForge Factory

Location: Hamburg, Germany
Large-scale solar installation for a metal fabrication plant, optimized to meet industrial energy demand while supporting Germany’s renewable transition goals. Includes automated load balancing.